Ordered on weekdays before 14:00 = shipped the same day and delivered the next day in 98% of cases. Free returns 30-day reflection period 1-year warranty

Water flow sensor

The YF-B2 water flow sensor is compact in size and easy to install. The sensor is mainly composed of a plastic valve body, a water flow rotor assembly and a Hall sensor. It is installed at the water inlet end of the gas boiler to detect water flow.

Technical Specifications:

  • Operating voltage range: DC 5~18V
  • Minimum rated operating voltage: DC 5V
  • Maximum operating current: 15mA (DC 5V)
  • Load capacity: ≤ 10mA (DC 5V)
  • Operating temperature range: ≤80 ℃
  • Application humidity range: 35% to 90% RH (non-condensing)
  • Permissible pressure resistance: Water pressure below 1.75 Mpa
  • Storage temperature: -25 ~ +80 ℃
  • Storage humidity: 25% ~ 95% RH
  • Liquid temperature max: 120°C

Wiring connection:

JST connector

Red wire: IN
Yellow wire: OUT
Black wire: GND

Output specifications:

  • Output pulse high level: > DC 4.5 V (input voltage DC 5 V)
  • Output pulse low level: < DC 0.5 V (input voltage DC 5 V)
  • Fine output (Flow -- pulse output): 1~ 25L/min ±3 %
  • Output pulse duty cycle: 50±10%
  • Output rise time: 0.04 μS
  • Output fall time: 0.18 μS
  • Flow - pulse characteristics: Horizontal test pulse frequency (Hz)=[ 11* Q]± 5 % (horizontal test) (Q is flow rate L/min)

Resistance to environmental influences:

  • Impact resistance: the product is well packaged and shows no abnormalities when freely dropped from a height of 50 cm in the X, Y, and Z directions onto a concrete surface. Accuracy varies within 5%.
  • Insulation resistance: The insulation resistance between the Hall sensor and the copper valve body is more than 100 MΩ. (DC 500V)
  • Heat resistance: in an environment of 80 ± 3 ℃ for 48 hours, back to normal temperature for 1-2 hours without abnormalities, and the parts have no cracks, loosening, expansion, deformation and other phenomena, and the accuracy changes within 10%.
  • Cold resistance: in -20±3 ℃ environment for 48 hours, back to normal temperature for 1-2 hours without abnormality, and the parts have no cracks, loosening, expansion, deformation and other phenomena, and the accuracy changes

 

Eight, flow --- pulse characteristics refer to the table F=11*Q

flow

pulse

error

min

max 

flow

pulse

error

min

max

2

22

± 1.020

22.44

21.56

6.1

67.1

±3.2

68.44

65.76

2.1

23.1

± 1.021

23.59

22.64

6.2

68.2

±3.3

69.56

66.90

2.2

24.2

± 1.022

24.68

23.72

6.3

69.3

±3.4

70.69

67.91

2.3

25.3

±1.023

25.83

24.79

6.4

70.4

±3.5

71.81

69.06

2.4

26.4

±1.024

26.93

25.87

6.5

71.5

±3.6

72.93

70.07

2.5

27.5

±1.025

28.08

26.95

6.6

72.6

±3.7

74.05

71.22

2.6

28.6

±1.026

29.17

28.03

6.7

73.7

±3.8

75.17

72.23

2.7

29.7

±1.027

30.32

29.11

6.8

74.8

±3.9

76.30

73.38

2.8

30.8

±1.028

31.42

30.18

6.9

75.9

±3.10

77.42

74.38

2.9

31.9

±1.029

32.57

31.26

7

77

±3.11

78.54

75.54

3

33

±1.030

33.66

32.34

7.1

78.1

±3.12

79.66

76.54

3.1

34.1

±1.031

34.82

33.42

7.2

79.2

±3.13

80.78

77.70

3.2

35.2

±1.032

35.90

34.50

7.3

80.3

±3.14

81.91

78.69

3.3

36.3

±1.033

37.06

35.57

7.4

81.4

±3.15

83.03

79.85

3.4

37.4

±1.034

38.15

36.65

7.5

82.5

±3.16

84.15

80.85

3.5

38.5

±1.035

39.31

37.73

7.6

83.6

±3.17

85.27

82.01

3.6

39.6

±1.036

40.39

38.81

7.7

84.7

±3.18

86.39

83.01

3.7

40.7

±1.037

41.55

39.89

7.8

85.8

±3.19

87.52

84.17

3.8

41.8

±1.038

42.64

40.96

7.9

86.9

±3.20

88.64

85.16

3.9

42.9

±1.039

43.80

42.04

8

88

±3.21

89.76

86.33

4

44

±1.040

44.88

43.12

8.1

89.1

±3.22

90.88

87.32

4.1

45.1

±1.041

46.05

44.20

8.2

90.2

±3.23

92.00

88.49

4.2

46.2

±1.042

47.12

45.28

8.3

91.3

±3.24

93.13

89.47

4.3

47.3

±1.043

48.29

46.35

8.4

92.4

±3.25

94.25

90.64

4.4

48.4

±1.044

49.37

47.43

8.5

93.5

±3.26

95.37

91.63

4.5

49.5

±1.045

50.54

48.51

8.6

94.6

±3.27

96.49

92.80

4.6

50.6

±1.046

51.61

49.59

8.7

95.7

±3.28

97.61

93.79

4.7

51.7

±1.047

52.79

50.67

8.8

96.8

±3.29

98.74

94.96

4.8

52.8

±1.048

53.86

51.74

8.9

97.9

±3.30

99.86

95.94

4.9

53.9

±1.049

55.03

52.82

9

99

±3.31

100.98

97.12

5

55

±1.050

56.10

53.90

9.1

100.1

±3.32

102.10

98.10

5.1

56.1

±1.051

57.28

54.98

9.2

101.2

±3.33

103.22

99.28

5.2

57.2

±1.052

58.34

56.06

9.3

102.3

±3.34

104.35

100.25

5.3

58.3

±1.053

59.52

57.13

9.4

103.4

±3.35

105.47

101.44

5.4

59.4

±1.054

60.59

58.21

9.5

104.5

±3.36

106.59

102.41

5.5

60.5

±1.055

61.77

59.29

9.6

105.6

±3.37

107.71

103.59

5.6

61.6

±1.056

62.83

60.37

9.7

106.7

±3.38

108.83

104.57

5.7

62.7

±1.057

64.02

61.45

9.8

107.8

±3.39

109.96

105.75

5.8

63.8

±1.058

65.08

62.52

9.9

108.9

±3.40

111.08

106.72

5.9

64.9

±1.059

66.26

63.60

10

110

±3.41

112.20

107.91

 
  • Water flow sensor
  • Compact size
  • Easy to install
  • Hall sensor

Why choose this product?

  • Small size – Takes up little space
  • Easy to install – Quick to place according to the text
  • Detects water flow – Measures the water flow in use
  • For gas boiler – Suitable at the water inlet
Specifications
ConnectionJST connector
Suitable forgas boiler
Materialplastic
TypeYF-B2
Storage temperature-25 ~ +80 ℃
Operating voltage rangeDC 5~18V
Minimum rated operating voltageDC 5V
Load capacity≤ 10mA (DC 5V)
Operating temperature range≤80 ℃
Application humidity range35% to 90% RH (non-freezing)
Permissible pressure resistanceWater pressure under 1.75 Mpa
Storage humidity25% ~ 95% RH
Max fluid temperature120°C
Output pulse high level> DC 4.5 V (input voltage DC 5 V)
Output pulse low level< DC 0.5 V (input voltage DC 5 V)
Fine output (flow -- pulse output)1~ 25L/min ±3 %
Output pulse duty cycle50±10%
Output rise time0.04 μS
Output fall time0.18 μS
Operating current15mA (DC 5V)

Frequently bought together

Total: € 16,90

Reviews

No reviews yet.

Write a review
Your rating

Shipping & returns

Shipping

  • Parcel with track & trace€ 7,70Within 24 hours
  • Pick up at PostNL location€ 7,40Within 24 hours
  • Letterbox parcel€ 3,70Within 2 business days
  • Letterbox parcel 24 hours€ 4,55Within 24 hours
  • Pick up in storeFree
All about shipping

Returns

Not satisfied? You have 30 days after delivery to return the product.

All about returns