SKU: OT3565 Article number: AA260 EAN: 8720618827210
Compact time relay for precise on- and off-delay switching. Ideal for automation, home automation, and test setups. Optocoupler isolation for high interference resistance. Settings are retained.
Supply voltage: 6–30 V DC
Trigger signal: High-level 3.0–24 V DC
Signal GND and system GND are separated for better EMI resistance
Can be linked if desired (common ground)
Relay switching capacity:
DC ≤30 V, max. 5 A
AC 220 V, max. 5 A
Isolation: optocoupler
Time setting range: 0.1 s to 999 min, continuously adjustable
Memory: parameters remain stored
Dimensions: 63 × 38 × 15 mm
OP: on-time (relay on)
CL: off-time (relay off)
LOP: number of cycles 1–999, “—” = unlimited
P1 – one-time delay after trigger (OP on, then off)
P1.1: retriggering during OP ignores the signal
P1.2: retriggering during OP restarts OP
P1.3: retriggering during OP resets; relay off, timing stops
P2 – off/on delay after trigger
Trigger → first CL (off), then OP (on), then off
P3.1 – cyclic after trigger
Trigger → OP (on) → CL (off) → repeat according to LOP
New trigger stops the cycle
P3.2 – cyclic without trigger
After power-on directly OP → CL → repeat according to LOP
P4 – signal monitoring
As long as the trigger signal is present, relay remains on
When the signal disappears: OP starts and then switches off
If a new signal arrives during OP, the time is cleared
Select mode: hold SET for 2 s → select P1.1–P4 with UP/DOWN.
Parameters: short press SET → set OP, CL, LOP with UP/DOWN.
Time scale: in the parameter screen, short press STOP to select the decimal:
xxx → seconds (1–999 s)
xx.x → tenths (0.1–99.9 s)
x.x.x → minutes (1–999 min)
Save: hold SET to confirm and return.
Emergency stop/manual control: in main screen, short press STOP to set relay ON/OFF.
Sleep mode:
C-P: display turns off after 5 min inactivity
O-d: display stays on
Switch: hold STOP for 2 s.
Relay contact is passive; requires its own power supply.
1 channel, only on/off function.
Keep the load within the specified current and voltage.
Pay attention to correct polarity and provide sufficient cooling at high currents.